Providing
Cleanroom Certification, ASHRAE 110 Testing, Calibration, Decontamination,
USP 797 Solutions, Compressed Air Line Testing, Environmental Monitoring
and Qualification Services
|
|
|
 |

|

|

|
|
|
Laboratory
Ventilation Management Seminar
May
21st, 2008
One Day Seminar
$249 per person
Using
ASHRAE 110 Tracer Gas Analysis
Performance Evaluation and Balancing of Laboratory Chemical
Hoods
for Safety, Engineering, Facilities, and Users Groups
During the past few years, it has become increasingly clear that the practice
of simply placing a Laboratory Chemical hood (formerly called a "Chemical
Fume Hood") into a room and adjusting the face velocity to a magical
number is no longer adequate. We are commonly called on to look at laboratory
ventilation in a much more responsible manner. Recent litigation has made
it dangerous not to take our responsibilities seriously. The cornerstone
of these programs is a good understanding of relevant industry standards
and guidelines including; ASHRAE 110-1995, ANSI/AIHA Z9.5-2003, and SEFA
1-2006.
Micro-Clean is presenting a class at our facility in Bethlehem, PA. We
anticipate representatives of the Safety, Engineering, and Maintenance
departments will benefit from this class. Ideally, we would get representatives
of multiple sites and organizations that use this equipment to attend.
Interaction with your peer groups would help you form strategies to deal
with the new challenges. Our training facility is well suited for this
purpose.
We will include both hands-on demonstration and lectures covering overall
strategy and industry standards. Class will begin at 9:00 a.m. Lunch will
be served. We will conclude by 4:00 p.m. The following will be covered:
| I. |
Introduction |
9:00am |
| II. |
Lecture
- Evolution
of the Laboratory Chemical Hood
- Specific
Terms and Definitions
- Airflow Measuring
Devices
- ASHRAE 110
Overview and Test Procedures
|
9:20am |
| III. |
Labs |
11:00am |
| IV. |
Lunch |
12:30am |
| V. |
Lecture
- CV vs. VAV
- Making It
Work-Real World Issues
- Anemometer
vs. Velgrid
- Standards
|
1:00pm |
| VI. |
Labs |
2:00pm |
| VII. |
Laboratory
Ventilation Management Plan/Wrap-up |
3:15pm |
| VII. |
Adjourn |
4:00pm |
Please call or email Amber Serfass at 800-523-9852 x277 or amberserfass@microcln.com
to confirm your interest in this class. Our intent is to limit the class
to the first 20 respondents to keep the day as interactive as possible.
|

|
Micro-Clean, Inc. • 177 N. Commerce Way •
Bethlehem, PA 18017
Phone: 1-800-523-9852 • Email: micro-clean@microcln.com